What are the EU CRA requirements in Annex I?

Annex I, Part I sets one general rule, an appropriate level of cybersecurity based on the risks, and 13 specific requirements, points (a) to (m): from shipping without known exploitable vulnerabilities and secure defaults to security updates, access control, encryption, logging and secure data deletion. They apply to products placed on the market from 11 December 2027.

Reviewed November 2026. 3 sources listed at the end of the page.

The general rule

Products must be designed, developed and produced to ensure an appropriate level of cybersecurity based on the risks (Annex I, Part I, point 1). The 13 specific requirements in point 2 apply "on the basis of the cybersecurity risk assessment" and "where applicable". That wording matters: you decide applicability in the risk assessment, and justify any requirement you treat as not applicable in the technical documentation (Article 13(3), 13(4)).

The 13 requirements

PointRequirementWhat it means in practice
(a)No known exploitable vulnerabilitiesShip without known exploitable vulnerabilities. The Commission treats a vulnerability as known when it is listed in public vulnerability databases or the manufacturer learns of it otherwise (guidance, points 233 and 234)
(b)Secure by defaultShip with a secure default configuration, with a way to reset to the original state; tailor-made business products can agree otherwise
(c)Security updatesVulnerabilities can be fixed through updates, with automatic security updates on by default where applicable, a clear opt-out, update notifications and the option to postpone
(d)Access controlProtect against unauthorised access with authentication, identity or access management, and report possible unauthorised access
(e)ConfidentialityProtect stored, transmitted or processed data, for example by state-of-the-art encryption at rest and in transit
(f)IntegrityProtect data, commands, programs and configuration against unauthorised manipulation, and report corruptions
(g)Data minimisationProcess only data that is adequate, relevant and limited to the intended purpose
(h)AvailabilityProtect essential and basic functions, also after an incident, including resilience against denial-of-service attacks
(i)Do no harm to othersMinimise the product's negative impact on services provided by other devices or networks
(j)Limit attack surfacesDesign to limit attack surfaces, including external interfaces
(k)Reduce incident impactUse exploitation mitigation mechanisms and techniques
(l)Security loggingRecord and monitor relevant internal activity, such as access to or changes of data, services or functions, with a user opt-out
(m)Secure deletion and transferLet users remove all data and settings permanently, and transfer data securely where transfer is possible

Part II of Annex I adds eight vulnerability handling requirements for the manufacturer's processes, including the SBOM. See vulnerability handling. To work through all 21 for one product, use the Annex I checklist.

How the requirements are assessed

  • Risk assessment firstArticle 13(3) requires the assessment to say whether and how each point (2) requirement applies and how it is implemented.
  • Standards laterHarmonised standards give a presumption of conformity once cited in the Official Journal (Article 27(1)). None had been cited as of 23 November 2026. The CEN-CENELEC standard on generic security requirements, prEN 40000-1-4, was still being drafted.
  • EvidenceTest reports verifying conformity with Part I belong in the technical documentation (Annex VII, point 6).

Points US teams ask about most

Known exploitable vulnerabilities. The requirement is about vulnerabilities that are both known and exploitable under practical operational conditions (Article 3(41)). The Commission does not expect a product to be free of every theoretical weakness (guidance, point 231), but a release gate that checks public vulnerability databases against your components is the obvious control.

Automatic updates. Point (c) calls for automatic security updates enabled by default "where applicable", with a clear opt-out and the option to postpone. The instructions must explain how to turn the default off (Annex II, point 8(e)).

Default passwords. The CRA does not list default passwords by name. Points (b) and (d), secure by default and protection from unauthorised access, are where a shared default password would fail.

Logging with opt-out. Point (l) asks for security-relevant logging with an opt-out for the user. Plan where logs are kept and how the opt-out works before the design freezes.

Penalties

Non-compliance with the Annex I requirements carries fines of up to €15 million or 2.5% of worldwide annual turnover, whichever is higher (Article 64(2)).

Common questions

Do all 13 requirements apply to every product?

They apply where applicable, based on the risk assessment (Annex I, Part I, point 2). Any requirement you treat as not applicable needs a clear justification in the technical documentation (Article 13(4)).

Is there a standard we can follow?

Not one that gives presumption of conformity yet. No CRA harmonised standard was cited in the Official Journal as of 23 November 2026; see the standards page for what is in progress.