CRA for Devices

What is ETSI EN 303 645, and does it meet the EU CRA?

ETSI EN 303 645 is the European baseline for consumer IoT security. The current version, V3.1.3 (2024-09), was adopted on 11 September 2024 and sets 13 groups of provisions, from no universal default passwords to input validation. It is not a harmonised standard under the RED or the CRA, so it gives no presumption of conformity.

Reviewed November 2026. 5 sources listed at the end of the page.

What the standard is

ETSI EN 303 645, "Cyber Security for Consumer Internet of Things: Baseline Requirements", sets high-level security and data protection provisions for consumer IoT devices connected to a network and their associated services. ETSI announced V3.1.3 on 31 October 2024. Its national transposition data gives the date of adoption as 11 September 2024 and the date for withdrawing conflicting national standards as 30 June 2025. ETSI's version directory shows no later version as of 23 November 2026.

Its scope lists examples such as connected toys and baby monitors, smoke detectors, door locks and window sensors, gateways and hubs, smart cameras, speakers and televisions, wearable health trackers, home alarm systems, appliances and smart home assistants. Devices used mainly in manufacturing, healthcare or other industrial applications are out of scope.

The provisions are outcome-focused, mixing requirements ("shall") with recommendations ("should"), and the introduction expects future versions to make some recommendations mandatory. ETSI TS 103 701 describes how to assess products against it.

The 13 provision groups, mapped to CRA Annex I

The headings are ETSI's. The right-hand column is our reading of the nearest CRA requirement, not an official mapping.

ClauseETSI EN 303 645 provisionNearest CRA Annex I point (our reading)
5.1No universal default passwordsPart I(2)(b) secure by default; (d) protection from unauthorised access
5.2Implement a means to manage reports of vulnerabilitiesPart II(5) coordinated vulnerability disclosure policy; (6) contact address
5.3Keep software updatedPart I(2)(c) security updates; Part II(2), (7), (8)
5.4Securely store sensitive security parametersPart I(2)(e) confidentiality
5.5Communicate securelyPart I(2)(e) confidentiality and (f) integrity
5.6Minimize exposed attack surfacesPart I(2)(j) limit attack surfaces
5.7Ensure software integrityPart I(2)(f) integrity
5.8Ensure that personal data is securePart I(2)(e) confidentiality
5.9Make systems resilient to outagesPart I(2)(h) availability of essential functions
5.10Examine system telemetry dataPart I(2)(l) recording and monitoring
5.11Make it easy for users to delete user dataPart I(2)(m) secure removal of data and settings
5.12Make installation and maintenance of devices easyAnnex II user information
5.13Validate input dataPart I(2)(f) integrity; (k) exploitation mitigation

Clause 6 adds data protection provisions, such as telling consumers what personal data is processed, by whom and for how long (provision 6-1). The nearest CRA points are Part I(2)(g), data minimisation, and the user information in Annex II.

Where the CRA asks for more

  • Support period lengthProvision 5.3-13 requires the maker to publish its defined support period, but sets no minimum. The CRA requires at least five years unless the product is expected to be in use for less, with the end date shown at purchase (Article 13(8) and 13(19)).
  • SBOMEN 303 645 mentions SBOM tools in its explanatory text. The CRA requires a machine-readable SBOM covering at least top-level dependencies (Annex I Part II(1)).
  • Reporting to authoritiesEN 303 645 has no duty to report to authorities. The CRA requires a 24-hour early warning for actively exploited vulnerabilities and severe incidents (Article 14).
  • Conformity and CE markingThe CRA requires a conformity assessment by class, technical documentation, an EU declaration of conformity and CE marking. EN 303 645 has none of these legal steps.
  • ScopeEN 303 645 covers consumer IoT only. The CRA covers business and industrial products and pure software too.

Why it gives no presumption of conformity

A standard gives a presumption of conformity with the CRA only once its reference is published in the Official Journal under the CRA (Article 27(1)). EN 303 645 is not. It is not on the Official Journal list of RED harmonised standards either: the consolidated list of 15 November 2026 contains EN 18031 for the RED cybersecurity requirements and no entry for EN 303 645. ETSI says it is working on the CRA's vertical standards; we found no primary source naming EN 303 645 as their basis.

How to use it anyway

For a consumer device, EN 303 645 is a practical checklist that covers much of CRA Annex I Part I. Treat its test results as evidence in your CRA risk assessment and technical documentation, then close the gaps above. Smart home security products, connected toys, wearables and smart speakers are Class I important products under the CRA, so plan for a notified body until CRA harmonised standards are cited.

Common questions

Is ETSI EN 303 645 mandatory in the EU?

No. It is a voluntary European standard. It is not cited as a harmonised standard under the RED or the CRA as of 23 November 2026.

Does EN 303 645 certification mean CRA compliance?

No. It covers much of Annex I Part I for consumer devices, but not the CRA's support period minimum, SBOM, reporting duty or conformity assessment and CE marking.

What is the latest version of ETSI EN 303 645?

V3.1.3 (2024-09), adopted on 11 September 2024. ETSI's version directory showed no later version as of 23 November 2026.

Get a shortlist of firms for your product

Send a short product brief. We reply by email with firms that do CRA assessment, documentation, testing or tooling work for products like yours, with the prices they publish and where we found them.

Free for makers. Prefer email? Write to

Product brief

Free for makers. We use your details only to reply. Your brief goes to no firm unless you ask for an introduction.