CRA for Devices

What is EN 18031, and does it still matter under the CRA?

EN 18031 is the three-part European standard for the Radio Equipment Directive's cybersecurity requirements, which have applied since 1 August 2025. Its references were published in the Official Journal on 30 January 2025, with restrictions. It supports the RED delegated act, which is repealed from 11 December 2027, and it is not a CRA harmonised standard.

Reviewed November 2026. 9 sources listed at the end of the page.

The three parts

PartEquipmentRED requirement supportedRestrictions
EN 18031-1:2024Internet connected radio equipment3(3)(d): no harm to the network or misuse of network resources2
EN 18031-2:2024Radio equipment processing data: internet-connected, childcare, toy and wearable radio equipment3(3)(e): personal data and privacy3
EN 18031-3:2024Internet connected radio equipment processing virtual money or monetary value3(3)(f): protection from fraud3

CEN and Cenelec drafted the three parts under the Commission's standardisation request C(2022)5637 of 5 August 2022. Implementing Decision (EU) 2025/138 of 28 January 2025 added them as rows 164 to 166 of the list of RED harmonised standards. The decision entered into force on publication, 30 January 2025, so the presumption of conformity runs from that date.

The restrictions in the Official Journal reference

All three parts were cited "with restrictions". Applying a part does not give a presumption of conformity in these cases:

  • All parts, notice 1The sections named "rationale" and "guidance" do not confer a presumption of conformity. The Commission notes they contain no specifications and refer to national standardisation deliverables.
  • All parts, notice 2No presumption if, when applying clauses 6.2.5.1 and 6.2.5.2 on default passwords, "the user is allowed not to set and use any password".
  • EN 18031-2, notice 3For toy and childcare equipment under clauses 6.1.3 to 6.1.6, no presumption if parental or guardian access control is not ensured.
  • EN 18031-3, notice 3No presumption at all for the secure update assessment criteria in clause 6.3.2.4.

The consolidated list of RED harmonised standards dated 15 November 2026 still carries the three references with the same notices. Later amendments to that list do not touch EN 18031.

What the restrictions do to your conformity route

Under RED Article 17(3), a maker that applies cited harmonised standards for the Article 3(3) requirements can use internal production control. Under Article 17(4), if it has not applied them, has applied them only in part, or none exist, the equipment goes to EU-type examination or full quality assurance with a notified body. In our reading, a design that falls into a restricted case, such as allowing the user to skip a password, is not covered by the presumption and moves you toward the notified body route for that requirement. Ask your test lab how it treats the notices.

Who has to care

Any maker selling Wi-Fi, Bluetooth, cellular or other radio equipment into the EU that falls under the RED delegated act: in practice internet-connected products, plus childcare equipment, toys and wearables. Many of these are also on the CRA's lists of important products, such as routers, smart home security products, connected toys and wearables.

What changes on 11 December 2027

  • RED delegated act repealedDelegated Regulation (EU) 2026/339 repeals 2022/30 with effect from 11 December 2027. Equipment placed on the market from 1 August 2025 to 10 December 2027 stays subject to RED market surveillance.
  • CRA appliesNew units must meet CRA Annex I. EN 18031 is cited under the RED, not under the CRA, so it gives no CRA presumption of conformity.
  • CertificatesA RED EU type-examination certificate can be relied on for the risks it covers until 11 June 2028 at the latest (CRA Article 69(1)). It does not cover CRA-only items such as vulnerability handling, data minimisation and attack-surface reduction (Commission guidance point 253).

Your EN 18031 test evidence is still a sound base for the CRA risk assessment, because the CRA's requirements include all the elements of RED Article 3(3)(d), (e) and (f) (CRA recital 30). See CRA vs the RED delegated act for the transition in detail.

Common questions

Is EN 18031 mandatory?

No standard is mandatory in itself. The RED cybersecurity requirements are mandatory for covered radio equipment since 1 August 2025; EN 18031 is one way to show conformity, with a presumption only outside the restricted cases.

Is EN 18031 a CRA harmonised standard?

No. It is cited under the Radio Equipment Directive. As of 23 November 2026 no CRA harmonised standard is cited.

Can I still use EN 18031 after December 2027?

For new units, the RED delegated act it supports no longer applies from 11 December 2027. Its test evidence can still feed your CRA risk assessment, and a RED certificate counts for the risks it covers until 11 June 2028.

Get a shortlist of firms for your product

Send a short product brief. We reply by email with firms that do CRA assessment, documentation, testing or tooling work for products like yours, with the prices they publish and where we found them.

Free for makers. Prefer email? Write to

Product brief

Free for makers. We use your details only to reply. Your brief goes to no firm unless you ask for an introduction.