CRA for Devices

Are routers, modems and switches Class I under the EU CRA?

Yes. Routers, modems and switches are Annex III, Class I, point 12 of Regulation (EU) 2024/2847. From 11 December 2027, new units need a notified body (Module B+C or H) unless a harmonised standard is applied in full, and none has been cited yet. Article 14 reporting already applies.

Reviewed November 2026. 9 sources listed at the end of the page.

The official description

Implementing Regulation (EU) 2025/2392, in force since 21 December 2025, gives the technical description the Commission uses for this category. It reads:

Routers are products with digital elements that establish and control the flow of data between different networks by selecting paths or routes using routing protocol mechanisms and algorithms, typically operating at the network layer.

Modems intended for the connection to the Internet are hardware products with digital elements that use digital modulation and demodulation techniques to convert analogue signals from and to digital signals for IP-based communication.

Switches are products with digital elements that provide connectivity between networked devices through packet forwarding mechanisms and that have a management plane, typically implemented at the data link or network layer.

Category recordOfficial
Annex III to Regulation (EU) 2024/2847 · Important, Class I · point 12
Category
Routers, modems intended for the connection to the internet, and switchesAnnex III, point 12
Class
Important, Class IArt. 7
Examples named
Wired and wireless routers, virtual routers and routers with or without modems; fibre modems, Digital Subscriber Line (DSL) modems, cable (DOCSIS) modems, satellite modems and cellular modems; managed switches, smart switches, multilayer switches, virtual security switches, programmable switches for software-defined networking and bridges such as wireless access pointsImplementing Regulation (EU) 2025/2392
Standard requested
Item 27 of the CRA standardisation request, due from the standards bodies by 31 January 2027C(2026) 7861, Annex I
Planned deliverable
ETSI EN 304 627, possibly in several parts, plus an IEC 62443-based security profileM/606 work programme, April 2025
Applies in full
11 December 2027Art. 71(2)
Taken from the official texts. The examples are illustrative, not a complete list (Implementing Regulation (EU) 2025/2392, recital 7).

Which conformity route applies

RouteWhat it involvesArticle
Self-assessment (Module A)Only if a harmonised standard, common specification or certification scheme at assurance level substantial or higher is applied in fullArt. 32(2)
EU-type examination (Module B) then Module CNotified body examines the design; you then control productionArt. 32(2)(a)
Full quality assurance (Module H)Notified body approves and monitors your quality systemArt. 32(2)(b)

Where things stand. Self-assessment needs a harmonised standard cited in the Official Journal, and none had been cited on 23 November 2026. NANDO listed no notified bodies under the CRA on the same date. If that is still the position when you place new units on the market from 11 December 2027, a Class I product will need a notified body.

Is your product in this category?

Class follows core functionality: the product's main features and technical capabilities, without which it would not meet its intended purpose (Article 7(1); Commission guidance, point 139). A product can perform other functions and still have this core functionality, and a product that merely integrates a component from this category is not in it because of that component (Article 7(1); Implementing Regulation (EU) 2025/2392, recitals 3 to 5). A product has only one core functionality for classification (guidance, point 144).

  • What countsWired, wireless and virtual routers, with or without modems; fibre, DSL, cable (DOCSIS), satellite and cellular modems; managed, smart, multilayer, virtual security and SDN-programmable switches; and bridges such as wireless access points.
  • Unmanaged switchesThe description covers switches that have a management plane. Our reading: a switch without one falls outside point 12 and is assessed on its own core functionality.
  • Routers with a firewallThe Commission's Example 63: a router that integrates a firewall is still a router, Class I. If a harmonised standard covers the router core, the maker can use internal control and treat the firewall's risks separately (guidance, points 152 and 154).
  • EnforcementWhen Germany's Bundestag passed the national CRA act on 15 October 2026, it also asked the BSI to check routers first.
  • RadioIf the product has a radio and can communicate over the internet, the Radio Equipment Directive's cybersecurity rules in Delegated Regulation (EU) 2022/30 have applied since 1 August 2025, usually shown with the EN 18031 standards. That act is repealed with effect from 11 December 2027, the day the CRA applies in full (Delegated Regulation (EU) 2026/339). See CRA vs the RED delegated act.

What changes on 11 December 2027

  • New unitsMust meet the essential requirements in Annex I, Parts I and II, and pass the conformity route above before they are placed on the EU market (Article 13, 32).
  • PaperworkTechnical documentation under Annex VII, an EU declaration of conformity and the CE marking, followed by the notified body number where Module H is used (Article 28, 30(4), 31).
  • Support periodAt least five years unless the product is expected to be in use for less, with the end date shown at purchase (Article 13(8), 13(19)). See support period.
  • Units already soldProducts placed on the market before that date are covered only if substantially modified afterwards, but Article 14 reporting already applies to them (Article 69(2), 69(3)).

What a US maker should do now

  • Confirm the classWrite down the core functionality and check it against the description above. The class checker walks through scope, exclusions and class.
  • Plan for the routeFor this class, assume third-party assessment unless a harmonised standard is cited and you apply it in full. Ask test labs and future notified bodies about capacity early.
  • Report nowSet up Article 14 reporting through ENISA's Single Reporting Platform: 24 hours for an early warning on an actively exploited vulnerability. See reporting.
  • Start the fileBegin the risk assessment, the SBOM and the vulnerability handling process. The Annex I checklist lists every requirement.

Common questions

Does a product that contains one of these become Important, Class I?

No, not by that fact alone. Article 7(1) says integrating a product with the core functionality of an Annex III category does not in itself make the host product subject to the stricter procedures, and the Commission applies the same logic to Annex IV (guidance, point 141).

Can we sell units we already ship after 11 December 2027 without changes?

Units placed on the market before 11 December 2027 are covered only if substantially modified afterwards (Article 69(2)). New units placed on the market from that date must comply. Reporting under Article 14 applies to all units since 11 September 2026 (Article 69(3)).

Get a shortlist of firms for your product

Send a short product brief. We reply by email with firms that do CRA assessment, documentation, testing or tooling work for products like yours, with the prices they publish and where we found them.

Free for makers. Prefer email? Write to

Product brief

Free for makers. We use your details only to reply. Your brief goes to no firm unless you ask for an introduction.