Which categories show up in OT
Industrial products are classified like any other, by core functionality. Implementing Regulation (EU) 2025/2392 names Fieldbus among the interfaces in point 10, and the amended standardisation request mentions firewalls and intrusion detection systems "specifically those intended for industrial use".
| Product | Category | Class | Route |
|---|---|---|---|
| PLC, controller, I/O module, sensor, HMI software | Not listed in Annex III or IV | Default | Module A self-assessment |
| Managed or programmable industrial switch, wireless access point | Routers, modems and switches | I (Annex III, point 12) | Notified body (Module B+C or H), or Module A if harmonised standards are applied in full |
| Industrial router or cellular gateway whose core function is routing | Routers, modems and switches | I (point 12) | Notified body (Module B+C or H), or Module A if harmonised standards are applied in full |
| Fieldbus or Ethernet interface card or module | Network interfaces | I (point 10) | Notified body (Module B+C or H), or Module A if harmonised standards are applied in full |
| Network management or configuration management system | Network management systems | I (point 6) | Notified body (Module B+C or H), or Module A if harmonised standards are applied in full |
| Real-time operating system sold as a product | Operating systems | I (point 11) | Notified body (Module B+C or H), or Module A if harmonised standards are applied in full |
| Industrial firewall, intrusion detection or prevention system | Firewalls, IDS and IPS | II (Annex III, Class II, point 2) | Notified body (Module B+C or H), or a certification scheme at "substantial" where available |
Complex systems and long lifecycles
The Commission's guidance has a section on complex systems with long design cycles, legacy architectures and interoperability constraints (points 29 to 32). These do not take a system out of scope. Where an essential requirement cannot be met because the system must interoperate with existing equipment, the manufacturer documents the constraint, assesses the risk and applies compensating measures. Its Example 10 allows an older protocol where interoperability requires it, provided the risks are mitigated and the secure protocol is enabled by default where both are supported.
Designs that predate the CRA do not automatically need a redesign. Units placed on the market after 11 December 2027 need a risk assessment under Article 13(2), and existing security measures can be relied on where they address the risks (points 33 and 34). Example 11 covers microcontrollers bought before the CRA and built into a system placed on the market after it.
Spare parts, repairs and support periods
- Identical spare partsOutside the CRA (Article 2(6)). The Commission applies this to a replacement CPU and to a whole replacement PLC supplied as spare parts (Example 39).
- Non-identical partsA replacement chip with a different cryptographic implementation is not identical and is a product in its own right (Example 37).
- Trusted environmentsA sensor without protection against physical attack can be limited to trusted environments, if the risk assessment and user information say so (Example 66).
- Support periodSet by expected use time. A PLC whose computing platform is replaced in a substantial modification may need a longer support period (Example 56).
IEC 62443 and the CRA
The European standards bodies' 2025 work programme plans CRA amendments to EN IEC 62443-4-1, 62443-4-2 and 62443-3-3 for operational technology. That is a standards-body plan, not a legal act, and no CRA harmonised standard had been cited by 23 November 2026. See CRA vs IEC 62443.
What to do first
- Inventory by core functionalityList each product sold separately, including software and spare parts, and classify each one.
- Set up reportingArticle 14 has applied since 11 September 2026, including to controllers already installed in the EU.
- Document constraintsWrite down where interoperability or certification limits a requirement, and the compensating measure.
- Plan Class I and II routesSwitches, routers and interfaces need a notified body unless standards are applied in full; firewalls and IDS always need a third-party route.
- Check NIS2 for your customersMany EU operators you sell to are NIS2 entities with supply chain duties. See CRA vs NIS2.
Sample classification record
- EX-PLC 40 controller
- Default. Core functionality is control, not listedArt. 7(1); Annex III
- EX-SW8 managed switch
- Class I, routers, modems and switchesAnnex III, point 12
- EX-FB2 Fieldbus card
- Class I, network interfacesAnnex III, point 10
- EX-FW1 industrial firewall
- Class II, firewalls and IDS/IPSAnnex III, Class II, point 2
- Spare CPU for EX-PLC 40
- Outside the CRA if identical and supplied as a spare partArt. 2(6)
Common questions
Is a PLC an important product under the CRA?
Not by itself. A PLC's core functionality is not listed in Annex III or IV, so it is in the default category unless it is sold mainly as one of the listed products. It still needs to meet Annex I.
Do we have to redesign products designed before the CRA?
Not necessarily. You need a risk assessment for units placed on the market from 11 December 2027, and you may rely on existing measures where they address the risks (Commission guidance, points 33 and 34).
Are replacement parts covered?
Identical spare parts made to the same specification are excluded (Article 2(6)). A part that differs in security-relevant ways, such as cryptography or secure boot, is a product in its own right (Example 37).
Sources
- Regulation (EU) 2024/2847 (Cyber Resilience Act), Official Journal text
- Commission Implementing Regulation (EU) 2025/2392, technical descriptions of important and critical products
- Commission guidance on the application of the CRA, C/2026/6013 (OJ C, 17 November 2026)
- Commission Implementing Decision C(2026) 7861 amending the CRA standardisation request
- CEN, CENELEC and ETSI, M/606 work programme (April 2025), a standards-body plan
- European Commission, CRA reporting obligations